Description
Testing Device HVTDA-50/70
- 50kV AC / 70kV DC Digital portable Hipot Tester
- 10” color, LCD screen display with adjustable brightness
- High accuracy voltage and current measurement: +/-1% of full scale
- Print or save test results and data transfer via USB
- Adjustable and Programmable test parameters such as target voltage, maximum leakage, speed rate, etc.
- Lightweight, rugged design, IP67-rated case with wheels and adjustable handle
- Ideal for field testing applications
- Minimal setup time and simple control panel
- Most accurate leakage current measurement
Typical areas of application for testing:
- Testing of high voltage cables
- Circuit breakers
- Bushings
- Reclosures
- Vacuum bottles
- Iso phase bus
- Motor and generator coils
- Rubber gloves
- Small Motors/Generators
- Withstand tests
The HVTDA-50/70 testing device consist of two separate units:
- control unit;
- high-voltage unit.
The control unit, based on an industrial computer, allows the device to be operated by means of a userfriendly interface displayed on a 10 inch full colour LCD screen.
The operator can set the maximum output voltage, maximum output current, test time and test report.
The output voltage can be adjusted automatically or manually as the operator prefers.
TECHNICAL DATA
DC OPERATION
• Maximum operating DC rectified voltage – 70 kV;
• Maximum operating DC rectified current – 20 mA;
• Relative DC voltage measurement error – 3%;
• Relative DC current measurement error – 3%.
AC OPERATION
• Maximum operating AC voltage (RMS) – 50 kV;
• Maximum operating AC current – 35 mA;
• Relative AC voltage measurement error – 3%;
• Relative AC current measurement error – 3%.
MAIN DATA
• Power Supply – 210 – 240 Vrms/50Hz
• Maximum output power, not less than 2 kVA
• Duty cycle: 15 min ON / 60 min OFF (at 1.5kVA)
• Duty cycle: 5 min ON / 60 min OFF (at 2kVA)
• Emergency stop button.
• Output (terminals/cables) for connection of sirens and signaling equipment.
• High voltage presence indication
• Automatic system for voltage control (adjustment of the V/s growth rate, voltage maintenance time, and automatic voltage drop)
• Digital screen for the indication of voltage and current measurement.
• USB port for data extraction
• Built-in timer / stopwatch.
• “Zero Start” interlock
• Maximum current setting
DIMMENSIONS
• Control unite – 600x400x220mm, 30kg
• HV unite – 750x400x460mm, 42kg
STANDARD DELIVERY
• HVTDA-50/70 testing system
• Connection cable, 2 m, for connecting the HV units to the operating unit
• HV connection cable, 2 m, with connection clip
• Earth cable, 3 m, with earth terminal – 2 pieces
• Mains supply cord, 3 m
• User manual
• Calibration certificate