Description
An semiautomatic testing system for performing dielectric tests on personal protective equipment
MSP-50-2 is a modern device for testing electrical insulating protective gloves, shoes and boots.
- Simultaneous testing 2 gloves/shoes
- Testing AC/DC voltage
- Safe design
- Measurement, adjustment, control and protection systems
- Automatic measurement process
- Clear presentation of parameters
- Intuitive and ergonomic operation
- Compliance with the harmonized standards EN 60903 and EN 50321, ASTM D120
- Color display
- User-friendly interface
- Data archiving
- Innovative solutions of test circuits – elimination of voltage fluctuations and stoppage of testing after breakdown on one of the circuits.
A stand for simultaneous testing – according to the type of measuring tank – 2 electrical insulating protective gloves, shoes and boots or 1 sleeves.
It consists of a measuring tank and a control unite with high voltage transformers, a control autotransformer with a drive, control systems and protections. Each measuring circuit is supplied from its own 50 kV 40mA high voltage test transformer. A test takes place simultaneously on all the circuits. Such a supply solution allows avoiding voltage fluctuations in case of a breakdown in one of the
items under testing.
The manual filling the items under testing with water up to the required level and its immersion in the measuring tank.
Testing of personal protective equipment:
- Gloves – 00, 0, 1, 2, 3, 4 class
- Boots – 0, 1, 2, 3, 4 class
- Sleeves – 0, 1, 2, 3, 4 class
TECHNICAL DATA
Power – single-phase AC supply voltage, – 230V (120V 60Hz to order).
Device parameters at AC high voltage sources:
- maximum operating voltage (RMS), – 50 kV;
- maximum operating current (RMS), – 40 mA.
Device parameters at AC high voltage sources in parallel mode:
- maximum operating voltage (RMS), – 40 kV;
- maximum operating current (RMS), – 80 mA.
Device parameters at AC high voltage sources in anityphase mode:
- maximum operating voltage (RMS), – 100 kV;
- maximum operating current (RMS), – 20 mA.
Two channels of leakage current measurement per glove separately.
Possibility of three modes of transformer connections: independently, counter-phase, parallel.
Ability to program the test mode according to user requirements.
Built-in timer.
Ability to print reports.
Power consumption, – max. 4 kVA.
Reduced output voltage and current measurement error, %, – max. 3.
Weight: 150kg
The volume of water: 80L
Overall dimensions: 1000x750x1800(H) mm
Operation modes of the MSP-50-2 device with additional test stands:
- Hot stick testing with SD-1/SD-3 stands. The transformers are switched in counterphase to obtain a voltage of 100kV.
- Voltage indicators testing with SW-1 stand. Test of voltage indicators from 1 to 50kV using a single transformer.
- Dielectrics mats/blankets testing with IMT-40 stand. The transformers are switched in parallel
for higher output power. - Dielectric covers testing with CS-1/CS-2 testing stand.
Błąd w tekście? Zaznacz, naciśnij Ctrl+Enter i wyślij nam zgłoszenie.
If you have found a spelling error, please, notify us by selecting that text and pressing Ctrl+Enter.